5.3.2.1.2.3. SERIAL PORT TRANSMISSION PARAMETERS CONFIGURATION
For proper operation of ADA-13040MG with device connected to his RS485/RS422 serial port, should be set the same transmission
parameters for both devices.
Select Basic Serial Settings and enter Baud Rate, Data Bits, Parity, Stop Bits, the same parameter like has device connected to
the serial port of the converter.
5.3.2.1.3. UDP SOCKETS CONFIGURATION
Choosing UDP Sockets is configured the serial port of ADA-13040MG converter for direct communication with PC or other device
connected to the network by the use of UDP socked. Data sending by application or other device/s to this port are transferred through
LAN/WAN to ADA-13040MG converter and are present on his serial port. Press [Apply] for save the configuration
5.3.2.1.3.1. UDP CLIENT & SERVER CONFIGURATION IN CASE OF MASTER DEVICE
After saving the UDP Sockets profile, will open section UDP Server Settings with operating parameters like on picture below. Set an
access to UDP server on e.g. 2101 port. Then select Automatically send serial data in section UDP Client Settings, this
automatically send received data by the use UDP client service to the SLAVE device connected to LAN/WAN through e.g. ADA-
13020, ADA-13028L, ADA-13040MG, ADA-13110, ADA14040, ADA-14040.
On lists Send data to the following network services are addresses of network devices and ports to which will be send data. In
field:
– Description - enter e.g. location of the converter and SLAVE device,
– Send To - enter IP address of e.g. converter, connected to SLAVE device,
– UDP Port - enter the number of port on which is working UDP Server of converter connected to SLAVE device and press [Add]
In the section Send data under any of the following conditions is recommended to set parameters like on picture bellow.
For saving the configuration of UDP client and server for MASTER device, press [Apply].
Fig. 19. Example configuration of the UDP server&client on converter connected to MASTER device